How to add water to Bosch wall-hung boiler: Hot topics and operation guides on the Internet in the past 10 days
Recently, with the arrival of the winter heating season, the use of Bosch wall-mounted boilers has become a hot topic on the Internet. Many users are concerned about how to correctly fill the wall-mounted boiler with water to ensure heating efficiency. This article will combine the hot content of the past 10 days to provide you with a detailed structured operation guide.
1. Statistics of hot topics on the entire network in the past 10 days

| Ranking | Topic keywords | Search volume (10,000 times) | Main discussion platform |
|---|---|---|---|
| 1 | Wall-hung boiler winter maintenance | 28.5 | Baidu, Zhihu |
| 2 | Bosch wall mounted boiler water filling | 19.3 | Douyin, Xiaohongshu |
| 3 | Heating system pressure abnormality | 15.7 | Station B, Home Appliances Forum |
2. Operation steps of adding water to Bosch wall-hung boiler
1.Preparation: Turn off the power of the wall-hung boiler, ensure that the system cools to normal temperature, and prepare a special water refill key (required for some models).
2.Check pressure gauge: The normal pressure should be maintained between 1-1.5Bar. If it is lower than 0.8Bar, water needs to be added.
| Pressure value (Bar) | Status description | Processing method |
|---|---|---|
| <0.5 | severe water shortage | Replenish water immediately and check for leaks |
| 0.8-1.0 | Mild dehydration | It is recommended to add water |
| >2.0 | Pressure is too high | Need to drain and relieve pressure |
3.Hydration operation:
• Locate the black fill valve on the bottom of the boiler (usually marked "Fill")
• Slowly turn the valve 90 degrees counterclockwise
• Observe that the pressure gauge rises to 1.2Bar and then turn off immediately
3. Frequently Asked Questions (Frequently Asked Questions in the Past 10 Days)
| question | solution |
|---|---|
| Pressure continues to drop after rehydration | Check whether the pipe interface is leaking and contact after-sales service if necessary |
| The water replenishment valve cannot be turned | Do not force the operation. It is recommended to use special tools or call for repair. |
| Abnormal noise occurs after adding water | There may be air in the system and it needs to be vented. |
4. Precautions
1. The frequency of water replenishment should not be too high. 1-2 times a month is the normal range. Frequent water replenishment requires checking the system sealing.
2. Different models of Bosch wall-mounted boilers may have operational differences. It is recommended to refer to the specific product manual.
3. If an E9 or other fault code appears during operation, stop operation immediately and contact professional maintenance personnel.
4. In areas with severe cold winter, it is recommended to check the pressure regularly to prevent the risk of frost cracking.
5. User experience sharing (from hot posts on social platforms)
@ Heating Master Wang Master: "Recently, 30% of the maintenance orders received are caused by incorrect water replenishment. Users are particularly reminded: when replenishing water, the wall-mounted boiler must be powered on but not turned on!"
@家小 expert: "Using the timer on your mobile phone to assist with water replenishment is particularly useful. Set a 2-minute reminder to avoid excessive pressure due to forgetting to turn off the valve."
Through the above structured guide, I believe you can complete the water filling operation of the Bosch wall-mounted boiler safely and efficiently. If you need more help, you can call Bosch’s official service hotline at 400-826-8484.